It can be used for the same application areas, but thanks to its low. Today most incremental encoders have a pushpull htl or rs422 ttl output driver. The qax module a, b, and z inputs accept only differential line driver rs 422 signals. I am purchasing an incremental encoder that has an rs422 line driver ouput. The differential receivers can be operated in rs422 or differential. This encoder features a 12 or bit absolute parallel gray code output, a selection line for count direction, and an output latch as standard. The rs 485standard is written to be electrically compatible with rs422. It is frequently used in legacy systems as a simple, economical solution. Eiatia422 defines a balanced differential interface. Rs 422 in this case is just restating the balanced 5 volt output which means there are a, a, b, b, z, z outputs.
The rs 485standard is written to be electrically compatible with rs 422. An rs485 driver must have the enable control signal. Because of this, a sinking input is required for proper operation. A special ic called a line receiver is used to receive the signal output from a line driver. Singleended line drivers ttl are not supported due to low noise immunity. The cmn on the qa module must be connected to the encoder, or the signals will not be read correctly. Use twisted pairs and shielded cables for the a and b signals. The renco r35i is an incremental rotary encoder without integral bearing and with optical scanning. The qax module a, b, and z inputs accept only differential line driver rs422 signals. Rs422, rs485 differential line driver texas instruments. It is recommended to use any rs422485 compatible receiver and provide a termination resistor based on the rs422485 specification for your specific voltage and data line length.
The rxtx converter converts a pushpull or npn encoder output to an. To enable the differential driver to be used, the rs422 standard uses a four conductor cable. I am purchasing an incremental encoder that has an rs 422 line driver ouput. It is recommended to use any rs 422 485 compatible receiver and provide a termination resistor based on the rs 422 485 specification for your specific voltage and data line length. The rs485standard is written to be electrically compatible with rs422. Shield cables and or individual wires to protect from emi. To enable the differential driver to be used, the rs 422 standard uses a four conductor cable. Max14890e incremental encoder interface for rs422, htl.
Encoder link, rs 422 driver receiver rev d3, page 241 description ichf is a robust line driver for industrial 5v control. The max3040max3045 is a family of 5v quad rs 485rs422 transmitters designed for digital data transmission over twistedpair balanced lines. Product overview about this product the pgx3 option allows the user to connect an incremental line driver encoder pg for motor speed feedback to the drive and take advantage of the closed loop flux vector control mode. The q1 module interfaces only to quadrature encoders with 5 v differential line driver rs 422 signals.
Rs485, rs422 and rs232 differences between the protocols. Always install the termination jumper to maintain signal integrity. Rs422 differential outputs provide excellent noise immunity, the ability to use long cable lengths, and. Industrial servo drive with biss position encoder interface.
Description the max14890e incremental encoder receiver contains four differential receivers and two singleended receivers. Signals can be provided in either a singleended multivoltage line driver ttl compatible when. Follow the encoder wiring scheme or pinout designated on the encoder datasheet. Adjust wiring for proper phasing in quadrature encoders. Synchronous serial interface ssi is a widely used serial interface standard for industrial applications between a master e.
The con485422ee4 has a db9 female connector on the rs232 serial port, and either a db9 male connector, rj45 female connector or terminal block with builtin 120 ohm termination option. Rs 422 cannot implement a truly multipoint communications network such as with eia485, however one driver can be connected to up to ten receivers. An rs422 driver may have this signal, but it is not. A particularly flatprofile and light alternative to the r35i available in the renco product line is the rcml15 rotary encoder. The differential receivers can be operated in rs422 or differential highthreshold logic htl modes and are optionally configurable for singleended ttlhtl operation. Encoder mile 5126400 cpt, 2 channels, with line driver rs. The disconnected or disabled condition of the line driver usually is referred to as the tristate 1 condition of the driver. With the optical transformation, a linecoded disc made of metal, plastic or glass and.
It is closely related to rs 423, which used the same signaling systems but on a different wiring arrangement. Motor pg feedback line driver interface installation manual. The interface board outputs are differential rs422 signals for channels a, b and the index pulse. This represents the rs422 connections of a device, card or converter. Ttl output is often called differential line driver output. Eia485 devices may be used in 422 circuits, but eia422 may not be used in 485 circuits because of the lack of an enable line. Differential output refers to the fact that each channel has a complement channel, i. Open collector an open collector is a sinking output.
The disconnected or disabled condition of the line driver usually is referred to as the tristate1 condition of the driver. Below is an example of a 4 wire cabling scheme as well as a 2 wire cabling scheme. It also allows you to sink or source more current than a totempole output. An rs422 driver may have this signal, but it is not always required. Interface to a 5v biss position encoder texas instruments. To illustrate their basic differences, a condensed description of each standard is presented in the following subsections. Watch the video to see incremental encoder output types explained. Rs 422 systems can transmit data at rates as high as 10 mbits, or may be sent on cables as long as 1,500 meters at lower rates. Defined by the tia standard, the rs422 is a transceiver that can be used with encoders as a differential line driver. Choosing between line driver, open collector, and push.
The connections for two devices with receive and transmit rs422 signals is shown in figure 1. Moel t incremental encoer encoder products company. So, according to the wiki, there indeed is no standard for the pin assignments of rs 422 on a db9 connector. And as i mentioned earlier would not be able to drive the ctrio inputs directly. The differential outputs can transmit the encoder signals over long distances and are typically connected to rs422 receiver encoder input terminals of either motion controllers or other position measuring instruments or devices. So, according to the wiki, there indeed is no standard for the pin assignments of rs422 on a db9 connector. It offers high noise immunity through its differential, symmetric signal transmission.
Defined by the tia standard, the rs 422 is a transceiver that can be used with encoders as a differential line driver. For the right application and paired with an appropriately sized pullup resistor, a 7273 line driver can be a very good solution. The terminal block plugs into the rs485rs422 port, providing screwlug wire terminations for the port. The pgx3 option allows the user to connect an incremental line driver encoder pg for motor speed feedback to the drive and take advantage of the closed loop flux vector control mode. Also, you may find that there are fewer devices supporting rs422.
The signal is output as a differential secondary signal, and thus is strong with respect to noise. Ttl format uses rs422 signaling, making it a good fit for noisy environments. Today most incremental encoders have a pushpull htl or rs422 ttl output driver, these have replaced most of the older output circuits like open collector npn, open collector pnp, voltage output. For connector pin configuration diagrams, see technical information or see connector pin configuration diagrams at encoder. Encoders frequently asked questions automationdirect. Logic and is also referred to as balanced differential line driver outputs. The device is optimized for high speeds over extended cable runs while maximizing tolerance to n. Rs422 will support pointtopoint, and multidrop circuits, but not multipoint. Rs422, rs485 line driver maxim integrated rs422, rs485. These monolithic quadruple differential line drivers with 3state outputs are designed to meet the requirements of ansi standards eiatia422b and rs485 and itu recommendation v. Rs422 is similar to rs232 protocol, and can be programmed in the same way, however, offers a few advantages and disadvantages. Connecting quadrature encoder with differential line.
Rs422 systems can transmit data at rates as high as 10. The chip offers ttlstyle output with a fivevolt regulated output. The max14783e is a halfduplex rs485422 transceiver that operates at either 3. Incremental encoder output signal overview rs422 output rs422 output types are typically referred to as balanced differential line driver outputs, whose characteristics are determined by the eia standard that defines the electrical specification and signal characteristics voltage levels, slew rates, etc. Output signals of incremental encoders encoder basics ics as. The interface board outputs are differential rs 422 signals for channels a, b and the index pulse. Rs422 cannot implement a truly multipoint communications network such as with eia485, however one driver can be connected to up to ten receivers. Eia485 devices may be used in 422 circuits, but eia 422 may not be used in 485 circuits because of the lack of an enable line. See parametric specs for rs485rs422 line driverreceivers 206.
To rnpico otherwise, instead of the dld 5v output configuration you could use the npn open collector 5 with appropriate pull up resistors or. The q1 module interfaces only to quadrature encoders with 5 v differential line driver rs422 signals. The differential receivers can be operated in rs 422 or differential highthreshold logic htl modes and are optionally configurable for singleended ttlhtl operation. A pushpull htl pushpull htl circuits, also known as totem pole, provide a signal level which corresponds to the applied supply voltage. Depending on the encoder, as well as the encoder cable, the maximum cable length or the maximum. Data from the encoder is sent with a max 491 transceiver in transmit mode. This is a differential signal and requires transmission line termination.
Smith serial communication products is your rs485 rs232 and rs422 authority for converters, repeaters, microprocessors, fiber optics, ethernet serial port server, ethernet serial products, mei, nodes and networks, usb, serial and digital io solutions, serial and analog io solutions including rs485, rs232, rs422, rs 485, rs 232, rs 422, telemetry, process control, translators, extenders. Output is standard gray code with options for natural binary or ssi compatible signals. Eiatia 422 defines a balanced differential interface. The connections for two devices with receive and transmit rs 422 signals is shown in figure 1. Rs 422 specifies differential signaling, with every data line paired with a dedicated return line. Available with 7pin ms style connector without index z. Meets rs 422 at 5 vdc supply index once per revolution gated to channel. One problem is that you need to purchase an rs422 port or at least an rs422 to rs232 converter, since pcs dont come standard with this interface. Ttl output generally conforms to the rs 422 standard, which specifies that. Its special properties are its compact design with 35 mm outside diameter and only 14 mm height as well as its easy, selfcentering mounting thanks to a patented slide lock. Additionally the rs422 standard allows for line impedances down to 50 ohms while supporting the high data rates.
Please refer to the table below for a simple example of a line driver. R35i selection guide the renco r35i is an incremental rotary encoder without integral bearing and with optical scanning. Encoder link, rs422 driverreceiver rev d3, page 241 description ichf is a robust line driver for industrial 5v control. The clock signals are rs 422 485 compatible, differential ttl, with 180 ohm termination. There are many way to terminate this signal and it depends on the characteristics of the device, in this case an ni 9411 digital input. Ssi is based on rs422 standards and has a high protocol efficiency in addition to its implementation over various hardware platforms, making it very popular among sensor manufacturers. The max14890e incremental encoder receiver contains four differential receivers and two. It was intended to replace the older rs 232c standard with a standard that offered much higher speed, better immunity from noise, and longer cable lengths. This is a 4wire connection, one pair of twisted wires is used for receive, the other for transmit. Max14890e incremental encoder interface for rs422, htl, and. Rs422, also known as tiaeia 422, is a technical standard originated by the electronic industries alliance that specifies electrical characteristics of a digital signaling circuit. Since both rs422 and rs485 are data transmission systems that use balanced differential signals, it is appropriate to discuss both systems in the same publication. In a differential pair of signals wires, the unwanted voltages are the same in each wire.
Rs422 line driver to ni digital input termination ni. The clock signals are rs422485 compatible, differential ttl, with 180 ohm termination. Incremental rotary encoders generate an output signal each time the shaft. Encoder mile 5126400 cpt, 2 channels, with line driver rs 422. However, i can not find much information on the electrical characteristics of the 9411. This represents the rs 422 connections of a device, card or converter. Rs 422 will support pointtopoint, and multidrop circuits, but not multipoint. Throughout this document the generic terms of rs422 and rs485 are used when referring to equipment and.
Serial synchronous interface ssi rotary encoder products. When in the on state, a line driver will supply vcc. Maximum data rates are 10 mbits at 12 m or 100 kbits at 1200 m. A differential line driver is used to help increase noise immunity. Smith serial communication products is your rs485 rs232 and rs422 authority for converters, repeaters, microprocessors, fiber optics, ethernet serial port server, ethernet serial products, mei, nodes and networks, usb, serial and digital io solutions, serial and analog io solutions including rs485, rs232, rs422, rs485, rs232, rs422, telemetry, process control, translators, extenders. Rs422 in this case is just restating the balanced 5 volt output which means there are a, a, b, b, z, z outputs.
952 1076 91 1599 629 963 572 252 1242 1558 70 707 1122 1486 629 788 981 1371 325 897 962 131 666 901 305 1515 882 1622 917 615 990 647 1107 817 1465 913 928